activity
20172022
most citedKAGRA: 2.5 Generation Interferometric Gravitational Wave Detector

535 citations · 833 across the 11 of their papers we have counts for

collaborators

12 papers

gr-qc2022

Input optics systems of the KAGRA detector during O3GK

T. Akutsu, M. Ando, K. Arai +246

KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with…

physics.ins-det2020★ 21 cited

Cryogenic suspension design for a kilometer-scale gravitational-wave detector

Takafumi Ushiba, Tomotada Akutsu, Yoichi Aso +43

We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises f…

gr-qc2020★ 9 cited

Overview of KAGRA : KAGRA science

KAGRA Collaboration, T. Akutsu, M. Ando +240

KAGRA is a newly build gravitational-wave observatory, a laser interferometer with 3 km arm length, located in Kamioka, Gifu, Japan. In this paper in the series of KAGRA-featured a…

astro-ph.IM2020★ 7 cited

Compact integrated optical sensors and electromagnetic actuators for vibration isolation systems in the gravitational-wave detector KAGRA

Tomotada Akutsu, Fabián Erasmo Peña Arellano, Ayaka Shoda +18

This paper reports on the design and characteristics of a compact module integrating an optical displacement sensor and an electromagnetic actuator for use with vibration-isolation…

physics.ins-det2019★ 16 cited

An arm length stabilization system for KAGRA and future gravitational-wave detectors

T. Akutsu, M. Ando, K. Arai +198

Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the a…

astro-ph.IM2019★ 13 cited

Application of the independent component analysis to the iKAGRA data

KAGRA Collaboration, T. Akutsu, M. Ando +244

We apply the independent component analysis (ICA) to the real data from a gravitational wave detector for the first time. Specifically we use the iKAGRA data taken in April 2016, a…

astro-ph.IM2019★ 59 cited

First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA

KAGRA Collaboration, T. Akutsu, M. Ando +198

KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we c…

physics.ins-det2019★ 14 cited

Vibration isolation system with a compact damping system for power recycling mirrors of KAGRA

Y. Akiyama, T. Akutsu, M. Ando +169

A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A sus…

gr-qc2018★ 535 cited

KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector

T. Akutsu, M. Ando, K. Arai +188

The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors wil…

gr-qc2017★ 86 cited

Construction of KAGRA: an Underground Gravitational Wave Observatory

T. Akutsu, M. Ando, S. Araki +222

Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a m…

gr-qc2017★ 53 cited

The status of KAGRA underground cryogenic gravitational wave telescope

KAGRA Collaboration, T. Akutsu, M. Ando +146

KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to…

physics.ins-det2017★ 20 cited

Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope

Yuta Michimura, Tomofumi Shimoda, Takahiro Miyamoto +36

KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions o…