most citedEvaluation of scatter rejection and correction performance of 2D antiscatter grids in cone beam computed tomography

19 citations · 32 across the 6 of their papers we have counts for

collaborators

6 papers

physics.med-ph2023★ 1 cited

A 2D antiscatter grid and scatter sampling based CBCT method for online dose calculations during CBCT guided radiation therapy of pelvis

Farhang Bayat, Brian Miller, Yeonok Park +7

Online dose calculations before radiation treatment have applications in dose delivery verification, plan adaptation, and treatment planning. We propose a novel CBCT imaging pipeli…

physics.med-ph2023

2D antiscatter grid and scatter sampling based CBCT pipeline for image guided radiation therapy

Farhang Bayat, Dan Ruan, Moyed Miften +1

Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring a…

physics.med-ph2023

Feasibility of dual-energy CBCT material decomposition in the human torso with 2D anti-scatter grids and grid-based scatter sampling

Cem Altunbas

Background: Dual-energy (DE) imaging techniques in cone-beam computed tomography (CBCT) have potential clinical applications, including material quantification and improved tissue…

physics.med-ph2022★ 12 cited

Concurrent kilovoltage CBCT imaging and megavoltage beam delivery: Suppression of cross-scatter with 2D antiscatter grids and grid-based scatter sampling

Farhang Bayat, Mohamed Elsayed Eldib, Brian Kavanagh +2

The concept of using kilovoltage (kV) and megavoltage (MV) beams concurrently has potential applications in cone beam computed tomography (CBCT) guided radiation therapy, such as s…

physics.med-ph2020★ 19 cited

Evaluation of scatter rejection and correction performance of 2D antiscatter grids in cone beam computed tomography

Yeonok Park, Timur Alexeev, Brian Miller +2

Purpose: We have been investigating 2D antiscatter grids (2D ASG) to reduce scatter fluence and improve image quality in cone beam computed tomography (CBCT). In this work, two dif…

physics.med-ph2020

Feasibility of 2D antiscatter grid concept for flat panel detectors: preliminary investigation of primary transmission properties

Cem Altunbas, Yuncheng Zhong, Chris C. Shaw

Suppressing the effects of scattered radiation in flat panel detector, FPD, based CBCT still remains to be a challenge. To address the scatter problem, we have been investigating t…