1.3k citations · 3.3k across the 44 of their papers we have counts for
46 papers
Data handling, production, and simulation in the Muon g-2 Experiment at Fermilab
2 Collaboration, David Aguillard, Talal Albahri +192
This paper details the computing strategies of the Muon g-2 Experiment at Fermilab, which measured the muon's anomalous magnetic moment with a precision of 127 ppb by processing ov…
Measurement of the Positive Muon Anomalous Magnetic Moment to 127 ppb
The Muon $g-2$ Collaboration, :, D. P. Aguillard +193
A new measurement of the magnetic anomaly of the positive muon is presented based on data taken from 2020 to 2023 by the Muon Experiment at Fermi National Accelerator L…
European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment
PIONEER Collaboration, A. Adelmann, W. Altmannshofer +76
PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantl…
Measured gain suppression in FBK LGADs with different active thicknesses
J. Yang, S. Braun, Q. Buat +16
In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with…
Measurements of a LYSO crystal array from threshold to 100 MeV
O. Beesley, J. Carlton, B. Davis-Purcell +16
We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calori…
Gain suppression study on LGADs at the CENPA tandem accelerator
S. Braun, Q. Buat, J. Ding +9
Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge i…
Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
D. P. Aguillard, T. Albahri, D. Allspach +190
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 an…
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
D. P. Aguillard, T. Albahri, D. Allspach +188
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We ha…
Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan
B. Acharya, C. Adams, A. A. Aleksandrova +176
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-1…
Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment
PIONEER Collaboration, W. Altmannshofer, H. Binney +58
The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are d…
PIONEER: Studies of Rare Pion Decays
PIONEER Collaboration, W. Altmannshofer, H. Binney +58
A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potent…
A Measurement of Proton, Deuteron, Triton and Alpha Particle Emission after Nuclear Muon Capture on Al, Si and Ti with the AlCap Experiment
AlCap Collaboration, Andrew Edmonds, John Quirk +24
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for…
Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab
T. Albahri, A. Anastasi, K. Badgley +174
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muo…
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
B. Abi, T. Albahri, S. Al-Kilani +234
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly . The anomaly is determined from the precision measurem…
Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab
T. Albahri, A. Anastasi, K. Badgley +170
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency of the muon to a combined precision of 0.46 parts per million with…
Nucleon Axial Radius and Muonic Hydrogen - A New Analysis and Review
Richard J. Hill, Peter Kammel, William J. Marciano +1
Weak capture in muonic hydrogen (H) as a probe of the chiral properties and nucleon structure predictions of Quantum Chromodynamics (QCD) is reviewed. A recent determination of…
Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications
J. Kaspar, A. T. Fienberg, D. W. Hertzog +19
We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorim…
Measurement of the Formation Rate of Muonic Hydrogen Molecules
MuCap Collaboration, V. A. Andreev, T. I. Banks +33
Background: The rate λ_ppμ characterizes the formation of ppμ molecules in collisions of muonic pμ atoms with hydrogen. In measurements of the basic weak muon capture reaction on t…
Mu2e Technical Design Report
L. Bartoszek, E. Barnes, J. P. Miller +260
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of m…
Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout
A. T. Fienberg, L. P. Alonzi, A. Anastasi +30
The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiP…
The New Muon g-2 experiment at Fermilab
Graziano Venanzoni
There is a long standing discrepancy between the Standard Model prediction for the muon g-2 and the value measured by the Brookhaven E821 Experiment. At present the discrepancy sta…
A high-pressure hydrogen time projection chamber for the MuCap experiment
J. Egger, D. Fahrni, M. Hildebrandt +21
The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, $μ^-…
Design and operation of a cryogenic charge-integrating preamplifier for the MuSun experiment
R. A. Ryan, F. Wauters, F. E. Gray +17
The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure t…
Mu2e Conceptual Design Report
The Mu2e Project, Collaboration, : +225
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better…