2.5k citations · 6.2k across the 22 of their papers we have counts for
22 papers
Search for inelastic dark matter with the CDMS II experiment
CDMS Collaboration, Z. Ahmed, D. S. Akerib +63
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory,…
Results from a Low-Energy Analysis of the CDMS II Germanium Data
CDMS Collaboration, Z. Ahmed, D. S. Akerib +62
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and Sep…
Results from the Final Exposure of the CDMS II Experiment
The CDMS Collaboration, Z. Ahmed
We report results from a blind analysis of the final data taken with the Cryogenic Dark Matter Search experiment (CDMS II) at the Soudan Underground Laboratory, Minnesota, USA. A t…
Analysis of the low-energy electron-recoil spectrum of the CDMS experiment
Z. Ahmed, D. S. Akerib, S. Arrenberg +54
We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the…
Search for Axions with the CDMS Experiment
CDMS Collaboration
We report on the first axion search results from the Cryogenic Dark Matter Search (CDMS) experiment at the Soudan Underground Laboratory. An energy threshold of 2 keV for electron-…
An Improved Limit on the Muon Electric Dipole Moment
G. W. Bennett, B. Bousquet, H. N. Brown +73
Three independent searches for an electric dipole moment (EDM) of the positive and negative muons have been performed, using spin precession data from the muon g-2 storage ring at…
A Search for WIMPs with the First Five-Tower Data from CDMS
CDMS Collaboration
We report first results from the Cryogenic Dark Matter Search (CDMS II) experiment running with its full complement of 30 cryogenic particle detectors at the Soudan Underground Lab…
Search for Lorentz and CPT Violation Effects in Muon Spin Precession
2 Collaboration, G. W. Bennett
The spin precession frequency of muons stored in the storage ring has been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT violation signatures were…
Final Report of the Muon E821 Anomalous Magnetic Moment Measurement at BNL
Muon, Collaboration, : +1
We present the final report from a series of precision measurements of the muon anomalous magnetic moment, a_mu = (g-2)/2. The details of the experimental method, apparatus, data t…
Limits on spin-dependent WIMP-nucleon interactions from the Cryogenic Dark Matter Search
CDMS Collaboration
The Cryogenic Dark Matter Search (CDMS) is an experiment to detect weakly interacting massive particles (WIMPs) based on their interactions with Ge and Si nuclei. We report the res…
Beyond the CDMS-II Dark Matter Search: SuperCDMS
P. L. Brink, B. Cabrera, C. L. Chang +41
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle (WIMP) search at the Soudan Underground Laboratory sets the most stringent exclusion limits of any WIMP co…
The SuperCDMS Experiment
SuperCDMS Collaboration
WIMP-nucleon cross sections in the range 10^{-46} - 10^{-44} cm^2 may be probed by a ton-scale experiment with low energy thresholds and excellent discrimination of backgrounds. Be…
First Results from the Cryogenic Dark Matter Search in the Soudan Underground Lab
CDMS Collaboration
We report the first results from a search for weakly interacting massive particles (WIMPs) in the Cryogenic Dark Matter Search (CDMS) experiment at the Soudan Underground Laborator…
Precision Measurement of the Anomalous Magnetic Moment of the Muon
William Morse
A precision measurement of the anomalous magnetic moment (g-2) of the muon has been made by the E821 collaboration at BNL. This paper is a written version of a ``hot topics'' talk…
Experimental measurement of muon (g-2)
F. E. Gray
The muon (g-2) experiment at Brookhaven National Laboratory has measured the anomalous magnetic moment of the positive muon with a precision of 0.7 ppm. This paper presents that re…
New Results from the Muon g-2 Experiment
E. P. Sichtermann
The Muon g-2 collaboration has measured the anomalous magnetic g value, a = (g-2)/2, of the positive muon with an unprecedented uncertainty of 0.7 parts per million. The result, ba…
Measurement of the Muon Anomalous Magnetic Moment to 0.7 ppm
Yannis K. Semertzidis
The experimental method together with the analysis method and results of the data taken in 2000 and prospects of the muon anomalous magnetic and electric dipole moment experiments…
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.7 ppm
G. W. Bennett
A higher precision measurement of the anomalous g value, a_mu = (g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron, based on data colle…
Testing CPT and Lorentz Invariance with the Anomalous Spin Precession of the Muon
M. Deile, Muon g-2 Collaboration
This article discusses tests of CPT and Lorentz invariance with data from the muon g-2 experiment at Brookhaven National Laboratory. According to an extension of the Standard Model…
Precision Measurement of Muon g-2 at BNL
2 Collaboration, O. Rind
The Muon (g-2) Experiment (E821) at Brookhaven National Laboratory (BNL) has measured the anomalous magnetic moment of the positive muon to an unprecedented precision of 1.3 parts…
Precise Measurement of the Positive Muon Anomalous Magnetic Moment
H. N. Brown, Muon g-2 Collaboration
A precise measurement of the anomalous g value, a_mu=(g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron. The result a_mu^+=11 659 202(1…
Improved Measurement of the Positive Muon Anomalous Magnetic Moment
H. N. Brown
A new measurement of the positive muon's anomalous magnetic moment has been made at the Brookhaven Alternating Gradient Synchrotron using the direct injection of polarized muons in…