activity
19942026
most citedBranching ratios and spectral functions of tau decays: final ALEPH measurements and physics implications

351 citations · 1.8k across the 35 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

8 papers · 1 filter

physics.ins-det2026

Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3

The CMS BRIL Collaboration, Eliana Acurio, Ying An +111

The Fast Beam Condition Monitor (BCM1F) has been used at the CMS Experiment since the first LHC circulating beams in 2008. Originally meant as a beam-induced background monitor for…

physics.ins-det2025

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

G. Auzinger, H. Bakhshiansohi, A. E. Dabrowski +40

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and…

physics.ins-det2024★ 1 cited

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

The Tracker Group of the CMS Collaboration

High-luminosity particle collider experiments such as the ones planned at the High-Luminosity Large Hadron Collider require ever-greater vertexing precision of the tracking detecto…

physics.ins-det2024

Beam Test Performance Studies of CMS Phase-2 Outer Tracker Module Prototypes

The Tracker Group of the CMS Collaboration

A new tracking detector will be installed as part of the Phase-2 upgrade of the CMS detector for the high-luminosity LHC era. This tracking detector includes the Inner Tracker, equ…

physics.ins-det2023

Evaluation of Planar Silicon Pixel Sensors with the RD53A Readout Chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Tracker Group of the CMS Collaboration

The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to cms. The increased luminosity during this…

physics.ins-det2017★ 8 cited

Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

M. Dragicevic, M. Friedl, J. Hrubec +481

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…

physics.ins-det2009★ 12 cited

Performance studies of the CMS Strip Tracker before installation

CMS Tracker Collaboration

In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber o…

physics.ins-det1999★ 2 cited

Monitoring the Stability of the ALEPH Vertex Detector

G. Sguazzoni

The ALEPH Silicon Vertex Detector features an optical fibre laser system to monitor its mechanical stability. The operating principle and the general performance of the laser syste…