51 citations · 290 across the 16 of their papers we have counts for
8 papers · 1 filter
Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons
The Tracker Group of the CMS Collaboration
High-luminosity particle collider experiments such as the ones planned at the High-Luminosity Large Hadron Collider require ever-greater vertexing precision of the tracking detecto…
Beam Test Performance Studies of CMS Phase-2 Outer Tracker Module Prototypes
The Tracker Group of the CMS Collaboration
A new tracking detector will be installed as part of the Phase-2 upgrade of the CMS detector for the high-luminosity LHC era. This tracking detector includes the Inner Tracker, equ…
Evaluation of Planar Silicon Pixel Sensors with the RD53A Readout Chip for the Phase-2 Upgrade of the CMS Inner Tracker
The Tracker Group of the CMS Collaboration
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to cms. The increased luminosity during this…
Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation
The Tracker Group of the CMS Collaboration
The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5 cms. This High Luminosity upgr…
Testing of planar hydrogenated amorphous silicon sensors with charge selective contacts for the construction of 3D- detectors
M. Menichelli, M. Bizzarri, M. Boscardin +29
Hydrogenated Amorphous Silicon (a-Si:H) is a material well known for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and…
Hydrogenated amorphous silicon detectors for particle detection, beam flux monitoring and dosimetry in high-dose radiation environment
Mauro Menichelli, Maurizio Boscardin, Michele Crivellari +14
Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have b…
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
M. Dragicevic, M. Friedl, J. Hrubec +481
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…
Performance studies of the CMS Strip Tracker before installation
CMS Tracker Collaboration
In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber o…