activity
19942025
most citedProduction of pi+, K+, K0, K*0, phi, p and Lambda-0 in Hadronic Z0 Decays

120 citations · 588 across the 19 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

9 papers · 1 filter

physics.ins-det2024★ 1 cited

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

The Tracker Group of the CMS Collaboration

High-luminosity particle collider experiments such as the ones planned at the High-Luminosity Large Hadron Collider require ever-greater vertexing precision of the tracking detecto…

physics.ins-det2024

Beam Test Performance Studies of CMS Phase-2 Outer Tracker Module Prototypes

The Tracker Group of the CMS Collaboration

A new tracking detector will be installed as part of the Phase-2 upgrade of the CMS detector for the high-luminosity LHC era. This tracking detector includes the Inner Tracker, equ…

physics.ins-det2023

Evaluation of Planar Silicon Pixel Sensors with the RD53A Readout Chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Tracker Group of the CMS Collaboration

The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to cms. The increased luminosity during this…

physics.ins-det2022

Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation

The Tracker Group of the CMS Collaboration

The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5 cms. This High Luminosity upgr…

physics.ins-det2017★ 8 cited

Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

M. Dragicevic, M. Friedl, J. Hrubec +481

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…

physics.ins-det2016★ 22 cited

Modeling of Radiation Damage Effects in Silicon Detectors at High Fluences HL-LHC with Sentaurus TCAD

Daniele Passeri, Francesco Moscatelli, Arianna Morozzi +1

In this work we propose the application of an enhanced radiation damage model based on the introduction of deep level traps / recombination centers suitable for device level numeri…

physics.ins-det2016★ 53 cited

Combined Bulk and Surface Radiation Damage Effects at Very High Fluences in Silicon Detectors: Measurements and TCAD Simulations

F. Moscatelli, D. Passeri, A. Morozzi +3

In this work we propose a new combined TCAD radiation damage modelling scheme, featuring both bulk and surface radiation damage effects, for the analysis of silicon detectors aimed…

physics.ins-det2016★ 7 cited

Measurements and TCAD Simulations of Bulk and Surface Radiation Damage Effects in Silicon Detectors

F. Moscatelli, P. Maccagnani, D. Passeri +7

In this work we propose the application of a radiation damage model based on the introduction of deep level traps/recombination centers suitable for device level numerical simulati…

physics.ins-det2009★ 12 cited

Performance studies of the CMS Strip Tracker before installation

CMS Tracker Collaboration

In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber o…