411 citations · 562 across the 13 of their papers we have counts for
11 papers · 1 filter
The CMS Barrel Timing Layer: test beam confirmation of module timing performance
F. Addesa, P. Akrap, A. Albert +127
First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedent…
Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector
F. Addesa, T. Anderson, P. Barria +68
For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, t…
Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons
The Tracker Group of the CMS Collaboration
High-luminosity particle collider experiments such as the ones planned at the High-Luminosity Large Hadron Collider require ever-greater vertexing precision of the tracking detecto…
Beam Test Performance Studies of CMS Phase-2 Outer Tracker Module Prototypes
The Tracker Group of the CMS Collaboration
A new tracking detector will be installed as part of the Phase-2 upgrade of the CMS detector for the high-luminosity LHC era. This tracking detector includes the Inner Tracker, equ…
Evaluation of Planar Silicon Pixel Sensors with the RD53A Readout Chip for the Phase-2 Upgrade of the CMS Inner Tracker
The Tracker Group of the CMS Collaboration
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to cms. The increased luminosity during this…
Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence
A. Bornheim, W. Lustermann, K. Stachon +27
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in…
Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation
The Tracker Group of the CMS Collaboration
The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5 cms. This High Luminosity upgr…
Toward the End-to-End Optimization of Particle Physics Instruments with Differentiable Programming: a White Paper
Tommaso Dorigo, Andrea Giammanco, Pietro Vischia +33
The full optimization of the design and operation of instruments whose functioning relies on the interaction of radiation with matter is a super-human task, given the large dimensi…
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
R. Abbott, A. Abreu, F. Addesa +196
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event re…
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
M. Dragicevic, M. Friedl, J. Hrubec +481
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…
Performance studies of the CMS Strip Tracker before installation
CMS Tracker Collaboration
In March 2007 the assembly of the Silicon Strip Tracker was completed at the Tracker Integration Facility at CERN. Nearly 15% of the detector was instrumented using cables, fiber o…