activity
19992026
most citedSearch for supersymmetry in hadronic final states with missing transverse energy using the variables AlphaT and b-quark multiplicity in pp collisions at 8 TeV

177 citations · 1.5k across the 39 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

7 papers · 1 filter

physics.ins-det2026

Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3

The CMS BRIL Collaboration, Eliana Acurio, Ying An +111

The Fast Beam Condition Monitor (BCM1F) has been used at the CMS Experiment since the first LHC circulating beams in 2008. Originally meant as a beam-induced background monitor for…

physics.ins-det2025

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

G. Auzinger, H. Bakhshiansohi, A. E. Dabrowski +40

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and…

physics.ins-det2024

Electronics design and testing of the CMS Fast Beam Condition Monitor for HL-LHC

K. Shibin, G. Auzinger, H. Bakhshiansohi +24

The high-luminosity upgrade of the LHC (HL-LHC) brings unprecedented requirements for precision bunch-by-bunch luminosity measurement and beam-induced background monitoring in real…

physics.ins-det2024

The CMS Fast Beam Condition Monitor for HL-LHC

G. Auzinger, H. Bakhshiansohi, A. Dabrowski +28

The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monito…

physics.ins-det2014★ 6 cited

Fast Beam Condition Monitor for CMS: performance and upgrade

Jessica L. Leonard, Alan Bell, Piotr Burtowy +14

The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector…

physics.ins-det2011★ 30 cited

Measurement of the CMS Magnetic Field

V. I. Klyukhin, A. Ball, F. Bergsma +16

The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a f…

physics.ins-det2010

Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC

R. S. Schmidt, A. J. Bell, E. Castro +8

The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditio…