activity
20142020
most citedProperties of GaAs:Cr-based Timepix detectors

21 citations · 54 across the 8 of their papers we have counts for

collaborators

8 papers

physics.med-ph2020★ 5 cited

Visualization of radiotracers for SPECT imaging using a Timepix detector with a coded aperture

V. Rozhkov, G. Chelkov, I. Hernández +8

The work shows the ability to visualize radiotracers used in SPECT with a system based on a coded aperture mask and a hybrid pixel Timepix detector with the CdTe sensor. Characteri…

physics.ins-det2017★ 21 cited

Properties of GaAs:Cr-based Timepix detectors

P. Smolyanskiy, G. Chelkov, S. Kotov +5

It is the hybrid pixel detector technology which brought to the X-ray imaging a low noise level at a high spatial resolution, thanks to the single photon counting. However, silicon…

physics.med-ph2017

Fast optimal decomposed modification of FDK with potential decreasing of memory consuming

Vladyslav Andriiashen, Danila Kozhevnikov

We present a new algorithm for 3D cone-beam tomography. The algorithm is based on decomposition of the cone-beam backprojection operation and angular decimation. It has computation…

physics.ins-det2017

Response of Timepix detector with GaAs:Cr and Si sensor to heavy ions

S. M. Abu Al Azm, G. Chelkov, D. Kozhevnikov +5

The response of the Timepix detector to neon ions with kinetic energy 77 and 158.4 MeV has been studied at the cyclotron U-400M of the JINR Flerov Laboratory of Nuclear Reaction. S…

physics.ins-det2017★ 10 cited

Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up

H. Abramowicz, A. Abusleme, K. Afanaciev +57

A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The obj…

physics.ins-det2015★ 17 cited

Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip

A. P. Butler, P. H. Butler, S. T. Bell +14

This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured…

physics.ins-det2015

Alignment and resolution studies of a MARS scanner

A. P. Butler, P. H. Butler, S. T. Bell +9

The MARS scanner is designed for the x-ray spectroscopic study of samples with the aid of computer tomography methods. Computer tomography allows the reconstruction of slices of an…

physics.ins-det2014★ 1 cited

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

The FCAL Collaboration, H. Abramowicz, A. Abusleme +66

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detec…