The possibility of absolute calibration of analog detectors by using parametric down-conversion: a systematical study
arXiv:quant-ph/0511093 · doi:10.1364/JOSAB.23.002185
Abstract
Accurate calibration of photodetectors both in analog and in photon-counting regime is fundamental for various scientific applications, which range from "traditional" quantum optics to the studies on foundations of quantum mechanics, quantum cryptography, quantum computation, etc. In this paper we systematically study the possibility of the absolute calibration of analog photo-detectors based on the properties of parametric amplifiers. Our results show that such a method can be effectively developed with interesting possible metrological applications.
References in corpus (5)
- Quantum key distribution using gaussian-modulated coherent states
- Research on Hidden Variable Theories: a review of recent progresses
- Detection of sub-shot-noise spatial correlation in high-gain parametric down-conversion
- Twin-photon techniques for photo-detector calibration
- Conditioned Unitary Transformation on biphotons
Cited by in corpus (20)
- Real applications of quantum imaging
- Measurement of sub-shot-noise spatial correlations without subtraction of background
- Photon number correlation for quantum enhanced imaging and sensing
- Systematic analysis of SNR in bipartite Ghost Imaging with classical and quantum light
- Detection of multimode spatial correlation in PDC and application to the absolute calibration of a CCD camera
- The Deep Space Quantum Link: Prospective Fundamental Physics Experiments using Long-Baseline Quantum Optics
- Absolute calibration of an EMCCD camera by quantum correlation linking photon counting to analog regime
- Self consistent, absolute calibration technique for photon number resolving detectors
- Absolute detector calibration using twin beams
- Absolute calibration of a CCD camera with twin beams
- Low-noise macroscopic twin beams
- Quantum differential ghost microscopy
- Absolute calibration of photodetectors: photocurrent multiplication versus photocurrent subtraction
- Analysis of the possibility of analog detectors calibration by exploiting Stimulated Parametric Down Conversion
- Transmission Estimation at the Cramér-Rao Bound for Squeezed States of Light in the Presence of Loss and Imperfect Detection
- Absolute calibration of Analog Detectors using Stimulated Parametric Down Conversion
- Quantum Conformance Test
- Transmission Estimation at the Fundamental Quantum Cramér-Rao Bound with Macroscopic Quantum Light
- Nonlinear power dependence of the spectral properties of an optical parametric oscillator below threshold in the quantum regime
- Intensity correlations in the Wigner representation