Effect of Optical Coating and Surface Treatments on Mechanical Loss in Fused Silica
arXiv:physics/9911040 · doi:10.1063/1.1291872
Abstract
We report on the mechanical loss in fused silica samples with various surface treatments and compare them with samples having an optical coating. Mild surface treatments such as washing in detergent or acetone were not found to affect the mechanical loss of flame-drawn fused silica fibers stored in air. However, mechanical contact (with steel calipers) significantly increased the loss. The application of a high-reflective optical coating of the type used for the LIGO test masses was found to greatly increase the mechanical loss of commercially polished fused silica microscope slides. We discuss the implications for the noise budget of interferometers.
7 pages, 2 figures. Accepted for publication in the Proceedings of the Third Eduardo Amaldi Conference on Gravitational Waves, July 12-16, 1999. Updated version contains a correction of Eq. 3 and an estimate for the loss angle of a LIGO coating. (Neither of these revisions are included in the version published in the conference proceedings.)