Abstract
The alignment procedure of the Silicon Microstrip Tracker, SMT, and the Central Fiber Tracker, CFT, is described. Alignment uncertainties and resulting systematic errors in physics analyses are addressed.
20 pages, 33 figures, presented at workshop on Tracking In high Multiplicity Environments (TIME'05) Zurich, October 3-7, 2005. Proceedings Nucl. Inst. Methods A