LED Monitoring System for the BTeV Lead Tungstate Crystal Calorimeter Prototype
arXiv:physics/0311119 · doi:10.1016/j.nima.2004.06.161
Abstract
We report on the performance of a monitoring system for a prototype calorimeter for the BTeV experiment that uses Lead Tungstate crystals coupled with photomultiplier tubes. The tests were carried out at the 70 GeV accelerator complex at Protvino, Russia.
arXiv comment12 pages, 8 figures, LaTeX2e, revised version
References in corpus (3)
Cited by in corpus (5)
- Design and performance of LED calibration system prototype for the lead tungstate crystal calorimeter
- Correlation of Beam Electron and LED Signal Losses under Irradiation and Long-term Recovery of Lead Tungstate Crystals
- Performance of a fine-sampling electromagnetic calorimeter prototype in the energy range from 1 to 19 GeV
- Study of Possible Scintillation Mechanism Damage in PbWO4 Crystals After Pion Irradiation
- The automatic gain-matching in the PIBETA CsI calorimeter