Precision frequency measurement of visible intercombination lines of strontium
arXiv:physics/0309014 · doi:10.1103/PhysRevLett.91.243002
Abstract
We report the direct frequency measurement of the visible 5s S-5s 5pP intercombination line of strontium that is considered a possible candidate for a future optical frequency standard. The frequency of a cavity-stabilized laser is locked to the saturated fluorescence in a thermal Sr atomic beam and is measured with an optical-frequency comb-generator referenced to the SI second through a GPS signal. The Sr transition is measured to be at 434 829 121 311 (10) kHz. We measure also the Sr-Sr isotope shift to be 163 817.4 (0.2) kHz.
4 pages, 4 figures. To be published on Phys. Rev. Lett. To be published on Phys. Rev. Lett
Cited by in corpus (6)
- Optical atomic coherence at the one-second time scale
- Fourier-transform spectroscopy of Sr2 and revised ground state potential
- Cooling and trapping of ultra-cold strontium isotopic mixtures
- Laser cooling and trapping of atomic strontium for ultracold atom physics, high-precision spectroscopy and quantum sensors
- A high stability semiconductor laser system for a Sr-based optical lattice clock