Pulse height measurements and electron attachment in drift chambers operated with Xe,CO2 mixtures
arXiv:physics/0303059 · doi:10.1016/S0168-9002(02)02083-1
Abstract
We present pulse height measurements in drift chambers operated with Xe,CO2 gas mixtures. We investigate the attachment of primary electrons on oxygen and SF6 contaminants in the detection gas. The measurements are compared with simulations of properties of drifting electrons. We present two methods to check the gas quality: gas chromatography and Fe55 pulse height measurements using monitor detectors.
arXiv comment19 pages, 16 figures
References in corpus (1)
Cited by in corpus (6)
- Measurement of electrons from semileptonic heavy-flavour hadron decays in pp collisions at = 7 TeV
- Transition Radiation Detectors
- Energy loss of pions and electrons of 1 to 6 GeV/c in drift chambers operated with Xe,CO2(15%)
- Transition Radiation Spectra of Electrons from 1 to 10 GeV/c in Regular and Irregular Radiators
- Space charge in drift chambers operated with the Xe,CO2(15%) mixture
- Position Reconstruction in Drift Chambers operated with Xe, CO2 (15%)