Abstract
Measurements of the shapes of scintillation pulses produced by nuclear recoils, alpha particles and photons in NaI(Tl) crystals at visible energies of 10-100 keV have been performed in order to investigate possible sources of background in NaI(Tl) dark matter experiments and, in particular, the possible origin of the anomalous fast time constant events observed in the UK Dark Matter Collaboration experiments at Boulby mine. Pulses initiated by X-rays (via photoelectric effect close to the surface of the crystal) were found not to differ from those produced by high-energy photons (via Compton electrons inside the crystal) within experimental errors. However, pulses induced by alpha particles (degraded from an external MeV source) were found to be ~10% faster than those of nuclear recoils, but insufficiently fast to account for the anomalous events.
arXiv comment9 pages, 2 figures, corrected misprints
Cited by in corpus (8)
- Limits on WIMP cross-sections from the NAIAD experiment at the Boulby Underground Laboratory
- Slow scintillation time constants in NaI(Tl) for different interacting particles
- Event categories in the EDELWEISS WIMP search experiment
- CsI(Tl) for WIMP dark matter searches
- Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module
- Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches
- Low energy fast events from radon progenies at the surface of a CsI(Tl) scintillator
- Pulse-Shape Discrimination of CaF2(Eu)