The CLEO-III Ring Imaging Cherenkov Detector
arXiv:hep-ex/9902023 · doi:10.1016/S0168-9002(99)00466-0
Abstract
The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.
Invited talk by R.J. Mountain at ``The 3rd International Workshop on Ring Imaging Cherenkov Detectors," a research workshop of the Israel Science Foundation, Ein-Gedi, Dead-Sea, Israel, Nov. 15-20, 1998, 14 pages, 9 figures
Cited by in corpus (6)
- Cherenkov Light Imaging - Fundamentals and recent Developments
- The Cleo III Ring Imaging Cherenkov Detector
- Measurement of the Decay Rate of Xi_c^0 --> pK^-K^-pi^+ Relative to Xi_c^0 --> Xi^-pi^+
- First Observation of the Exclusive Decays Lambda_c to Lambda pi+pi+pi-pi0 and Lambda_c to Lambda omega pi+
- BEAUTY'99 Conference Summary
- Search for $e^+e^- --> Lambda_b^0 barLambda_b^0 Near Threshold