Time Resolution and Linearity Measurements for a Scintillating Fiber Detector Instrumented with VLPC's

arXiv:hep-ex/9701016 · doi:10.1016/S0168-9002(97)00665-7

Abstract

The time resolution for a charged particle detection is reported for a typical scintillating fiber detector instrumented with Rockwell HISTE-IV Visible Light Photon Counters. The resolution measurements are shown to agree with a simple Monte Carlo model, and the model is used to make recomendations for improved performance. In addition, the gain linearity of a sample of VLPC devices was measured. The gain is shown to be linear for incident light intensities which produce up to approximately 600 photoelectrons per event.

arXiv comment18 pages, 14 figures; Submitted to Nucl. Instr & Meth. in Phys. Res. A; Please direct correspondence to [email protected]