Measurement of the Atmospheric Muon Spectrum from 20 to 3000 GeV
arXiv:hep-ex/0408114 · doi:10.1016/j.physletb.2004.08.003
Abstract
The absolute muon flux between 20 GeV and 3000 GeV is measured with the L3 magnetic muon spectrometer for zenith angles ranging from 0 degree to 58 degree. Due to the large exposure of about 150 m2 sr d, and the excellent momentum resolution of the L3 muon chambers, a precision of 2.3 % at 150 GeV in the vertical direction is achieved. The ratio of positive to negative muons is studied between 20 GeV and 500 GeV, and the average vertical muon charge ratio is found to be 1.285 +- 0.003 (stat.) +- 0.019 (syst.).
Total 32 pages, 9Figures
Cited by in corpus (36)
- Calculation of atmospheric neutrino flux using the interaction model calibrated with atmospheric muon data
- Spectrum of cosmic-ray nucleons and the atmospheric muon charge ratio
- The ALICE experiment: a journey through QCD
- Influence of hadronic interaction models and the cosmic ray spectrum on the high energy atmospheric muon and neutrino flux
- Measurement of the Atmospheric Muon Charge Ratio at TeV Energies with MINOS
- The Present and Future of QCD
- Measurement of the charge ratio of atmospheric muons with the CMS detector
- Study of cosmic ray interaction model based on atmospheric muons for the neutrino flux calculation
- Commissioning of the ATLAS Muon Spectrometer with Cosmic Rays
- Neutron monitors and muon detectors for solar modulation studies: Interstellar flux, yield function, and assessment of critical parameters in count rate calculations
- High-energy cosmic ray fluxes in the Earth atmosphere: calculations vs experiments
- Atmospheric lepton fluxes at very high energy
- Study of cosmic ray events with high muon multiplicity using the ALICE detector at the CERN Large Hadron Collider
- Measurement of TeV atmospheric muon charge ratio with the full OPERA data
- Beam-induced and cosmic-ray backgrounds observed in the ATLAS detector during the LHC 2012 proton-proton running period
- DAEMONFLUX: DAta-drivEn MuOn-calibrated atmospheric Neutrino Flux
- Atmospheric muon flux at PeV energies
- Measurement of the underground atmospheric muon charge ratio using the MINOS Near Detector
- Interpretation of the Underground Muon Charge Ratio
- Muon bundles as a sign of strangelets from the Universe
- Muon capture on light isotopes in Double Chooz
- Data-driven hadronic interaction model for atmospheric lepton flux calculations
- Reduction of the Uncertainty in the Atmospheric Neutrino Flux Prediction Below 1 GeV Using Accurately Measured Atmospheric Muon Flux
- Atmospheric muons measured with the KM3NeT detectors in comparison with updated numeric predictions
- Evaluation of cosmogenic production of and for rare-event physics using underground argon
- Atmospheric Neutrino Fluxes
- A method to measure the integral vertical intensity and angular distribution of atmospheric muons with a stationary plastic scintillator bar detector
- Origin Of The Cosmic Ray Positrons Observed Near Earth- Meson Decay Or Dark Matter Decay?
- Atmospheric muons charge ratio analysis at the INO-ICAL detector
- Measurement of the Multiple-Muon Charge Ratio in the MINOS Far Detector
- Measurements of the charge ratio and polarization of cosmic-ray muons with the Super-Kamiokande detector
- Measurement of cosmic muon charge ratio with the Large Volume Detector
- Shape of primary proton spectrum in multi-TeV region from data on vertical muon flux
- Muon bundles from extensive air showers
- On the deficit of calculated muon flux at sea level for energies GeV
- Probing Cosmic Ray Composition and Muon-philic Dark Matter via Muon Tomography