Studies of Electron Avalanche Behavior in Liquid Argon
arXiv:hep-ex/0204033 · doi:10.1109/TNS.2002.801490
Abstract
Electron avalanching in liquid argon is being studied as a function of voltage, pressure, radiation intensity, and the concentrations of certain additives, especially xenon. The avalanches produced in an intense electric field at the tip of a tungsten needle are initiated by ionization from a moveable americium (241Am) gamma ray source. Photons from xenon excimers are detected as photomultiplier signals in coincidence with the current pulse from the needle. In pure liquid argon the avalanche behavior is erratic, but the addition of even a small amount of xenon (>100ppm) stabilizes the performance. Similar attempts with neon (30%) as an additive to argon have been unsuccessful. Tests with higher energy gamma rays (57Co) yield spectra and other performance characteristics quite similar to those using the 241Am source. Two types of signal pulses are commonly observed: a set of pulses that are sensitive to ambient pressure, and a set of somewhat smaller pulses that are not pressure dependent.
7 pages, 8 figures
Cited by in corpus (9)
- Liquid noble gas detectors for low energy particle physics
- First results from cryogenic avalanche detectors based on gas electron multipliers
- Cryogenic avalanche detectors based on gas electron multipliers
- Pulse-shape discrimination and energy resolution of a liquid-argon scintillator with xenon doping
- The development of gaseous detectors with solid photocathodes for low temperature
- The science and technology of liquid argon detectors
- First demonstration of a bubble-assisted Liquid Hole Multiplier operation in liquid argon
- TRANSLATE -- A Monte Carlo Simulation of Electron Transport in Liquid Argon
- Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors