Measurement of Optical Response of a Detuned Resonant Sideband Extraction Interferometer
arXiv:gr-qc/0604078 · doi:10.1103/PhysRevD.74.022001
Abstract
We report on the optical response of a suspended-mass detuned resonant sideband extraction (RSE) interferometer with power recycling. The purpose of the detuned RSE configuration is to manipulate and optimize the optical response of the interferometer to differential displacements (induced by gravitational waves) as a function of frequency, independently of other parameters of the interferometer. The design of our interferometer results in an optical gain with two peaks: an RSE optical resonance at around 4 kHz and a radiation pressure induced optical spring at around 41 Hz. We have developed a reliable procedure for acquiring lock and establishing the desired optical configuration. In this configuration, we have measured the optical response to differential displacement and found good agreement with predictions at both resonances and all other relevant frequencies. These results build confidence in both the theory and practical implementation of the more complex optical configuration being planned for Advanced LIGO.
6 pages, 4 figures, for submission to Phys Rev Letters
Cited by in corpus (18)
- A Quantum-Enhanced Prototype Gravitational-Wave Detector
- Optical dilution and feedback cooling of a gram-scale oscillator to 6.9 mK
- Characterization of systematic error in Advanced LIGO calibration
- Advanced quantum techniques for future gravitational-wave detectors
- Gravitational-wave astronomy with a physical calibration model
- Double optical spring enhancement for gravitational wave detectors
- A route to observing ponderomotive entanglement with optically trapped mirrors
- Radiation-Pressure-Mediated Control of an Optomechanical Cavity
- Engineering the Optical Spring via Intra-Cavity Optical-Parametric Amplification
- Local readout enhancement for detuned signal-recycling interferometers
- Tuning Advanced LIGO to kilohertz signals from neutron-star collisions
- Using the etalon effect for in-situ balancing of the Advanced Virgo arm cavities
- Achieving the fundamental quantum limit of linear waveform estimation
- Experimental investigation of a control scheme for a zero-detuning resonant sideband extraction interferometer for next-generation gravitational-wave detectors
- Improving LIGO calibration accuracy by using time-dependent filters to compensate for temporal variations
- Finite Mirror Effects in Advanced Interferometric Gravitational Wave Detectors
- Development of signal-extraction scheme for Resonant Sideband Extraction
- Observation of an Optical Spring in a Robustly Controlled Signal-Recycled Michelson Interferometer