paper

Effect of Measurement on the Periodicity of the Coulomb Staircase of a Superconducting Box

arXiv:cond-mat/0305190 · doi:10.1103/PhysRevLett.92.057004

Abstract

We report on the effect of the back-action of a Single Cooper Pair Transistor electrometer (E) on the measurement of charge on the island of a superconducting box (B). The charge is e-periodic in the gate bias of B when E is operated near voltages 2Delta/e or 4Delta/e. We show that this is due to quasiparticle poisoning of B at a rate proportional to the number of quasiparticle tunneling events in E per second. We are able to eliminate this back action and recover 2e charge periodicity using a new measurement method based on switching current modulation of E.

4 pages, 4 figures, revised version

References in corpus (2)