Abstract
We report on the first astronomical observations with a photon counting pixel detector that provides arrival time- (delta t = 100ns) and energy- (delta E_gamma < 0.15eV) resolved measurements from the near IR through the near UV. Our test observations were performed by coupling this Transition Edge Sensor (TES) device to a 0.6m telescope; we have obtained the first simultaneous optical near-IR phase-resolved spectra of the Crab pulsar. A varying infrared turnover gives evidence of self-absorption in the pulsar plasma. The potential of such detectors in imaging arrays from a space platform are briefly described.
4 pages, 5 figures
References in corpus (2)
Cited by in corpus (15)
- A High Spectral Resolution Observation of the Soft X-ray Diffuse Background with Thermal Detectors
- Phase-resolved Crab Studies with a Cryogenic TES Spectrophotometer
- OPTIMA: A Photon Counting High-Speed Photometer
- Precisely determining photon-number in real-time
- Direct determination of quasar redshifts
- Near-infrared single-photon spectroscopy of a whispering gallery mode resonator using energy-resolving transition edge sensors
- Cherenkov Telescopes as Optical Telescopes for Bright Sources: Today's Specialised Thirty Metre Telescopes?
- Ultraviolet studies of interacting binaries
- Optical Spectrum of Main-, Inter- and Off-pulse Emission from Crab Pulsar
- ATLAST detector needs for direct spectroscopic biosignature characterization in the visible and near-IR
- Magnetospheric Scattering and Emission in Millisecond Pulsars
- First results of a cryogenic optical photon counting imaging spectrometer using a DROID array
- Boosting Photon-Number-Resolved Detection Rates of Transition-Edge Sensors by Machine Learning
- Simulated Extragalactic Observations with a Cryogenic Imaging Spectrophotometer
- Binary Classification of Light and Dark Time Traces of a Transition Edge Sensor Using Convolutional Neural Networks