A charge transfer inefficiency correction model for the Chandra Advanced CCD Imaging Spectrometer
arXiv:astro-ph/0407199 · doi:10.1117/12.550628
Abstract
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate CTI and spectral resolution degradation. We will discuss the characteristics of the damage, the detector and the particle background and how they conspire to degrade the instrument performance. We have developed a model for ACIS CTI which can be used to correct each event and regain some of the lost performance. The correction uses a map of the electron trap distribution, a parameterization of the energy dependent charge loss and the fraction of the lost charge re-emitted into the trailing pixel to correct the pixels in the event island. This model has been implemented in the standard Chandra data processing pipeline. Some of the correction algorithm was inspired by the earlier work on ACIS CTI correction by Townsley et al. (2000; 2002). The details of the CTI model and how each parameter improves performance will be discussed, as well as the limitations and the possibilities for future improvement.
12 pages, 12 figures, will appear in Proc. SPIE 5501
References in corpus (2)
Cited by in corpus (9)
- Chandra temperature profiles for a sample of nearby relaxed galaxy clusters
- Performance of the Charge Injection Capability of Suzaku XIS
- The Similarity of Broad Iron Lines in X-ray Binaries and Active Galactic Nuclei
- Deep Chandra observation of the galaxy cluster WARPJ1415.1+3612 at z=1: an evolved cool-core cluster at high-redshift
- The impact of CCD radiation damage on Gaia astrometry: I. Image location estimation in the presence of radiation damage
- Long-term trends in radiation damage of Chandra X-ray CCDs
- Comparing simulations and test data of a radiation damaged charge-couple device for the Euclid mission
- Fifteen years of the Advanced CCD Imaging Spectrometer
- Temperature dependence of charge transfer inefficiency in Chandra X-ray CCDs