Statistical Test of Optical Fibers for use in PMAS, the Potsdam Multi-Aperture Spectrophotometer
arXiv:astro-ph/0304288 · doi:10.1086/375696
Abstract
Focal ratio degradation measurements of optical fibers for the PMAS integral field instrument have been performed using the Photometric Testbench of the Potsdam Astrophysical Institute (AIP). An effort has been made to obtain sufficiently large statistical samples of individual fiber measurements. The optimization of the measurement process has made it possible to study quantitatively the effects of different coupling methods (air--glass vs.\ immersion) and of imperfections like defocus, lateral displacement, and angular misalignment. Furthermore, the effects of mechanical stress on focal ratio degradation have been investigated, confirming the presumed cause of modal noise which is known to limit the maximum signal-to-noise one can achieve with fiber-coupled echelle spectrographs.
arXiv comment14 pages, 19 figures. Accepted for publication by PASP, IP02-129, for July 2003
Cited by in corpus (7)
- SparsePak: A Formatted Fiber Field Unit for The WIYN Telescope Bench Spectrograph. I. Design, Construction, and Calibration
- PMAS, the Potsdam Multi-Aperture Spectrophotometer. I. Design, Manufacture, and Performance
- PMAS: The Potsdam Multi Aperture Spectrophotometer. II. The Wide Integral Field Unit PPak
- The HETDEX Instrumentation: Hobby-Eberly Telescope Wide Field Upgrade and VIRUS
- Focal ratio degradation in lightly-fused hexabundles
- Galaxy Kinematics with VIRUS-P: The Dark Matter Halo of M87
- Prototype development of the Integral-Field unit for VIRUS