Sub-electron read noise at MHz pixel rates
arXiv:astro-ph/0101409 · doi:10.1117/12.426988
Abstract
A radically new CCD development by Marconi Applied Technologies has enabled substantial internal gain within the CCD before the signal reaches the output amplifier. With reasonably high gain, sub-electron readout noise levels are achieved even at MHz pixel rates. This paper reports a detailed assessment of these devices, including novel methods of measuring their properties when operated at peak mean signal levels well below one electron per pixel. The devices are shown to be photon shot noise limited at essentially all light levels below saturation. Even at the lowest signal levels the charge transfer efficiency is good. The conclusion is that these new devices have radically changed the balance in the perpetual trade-off between readout noise and the speed of readout. They will force a re-evaluation of camera technologies and imaging strategies to enable the maximum benefit to be gained from these high-speed, essentially noiseless readout devices. This new LLLCCD technology, in conjunction with thinning (backside illumination) should provide detectors which will be very close indeed to being theoretically perfect.
arXiv commentContribution to SPIE conference proceedings HTML version: http://www.strw.leidenuniv.nl/~tubbs/papers/lllccd/sern_main.html
References in corpus (1)
Cited by in corpus (19)
- ULTRACAM: an ultra-fast, triple-beam CCD camera for high-speed astrophysics
- Photon counting strategies with low light level CCDs
- Quasi-Periodic Oscillations of ~ 15 minutes in the Optical Light Curve of the BL Lac S5 0716+714
- Imaging extrasolar planets by stellar halo suppression in separately-corrected color bands
- Scalable simultaneous multi-qubit readout with 99.99% single-shot fidelity
- Super-resolution microscopy of single atoms in optical lattices
- Diffraction-limited 800nm imaging with the 2.56m Nordic Optical Telescope
- Silicon Detector Arrays with Absolute Quantum Efficiency over 50% in the Far Ultraviolet for Single Photon Counting Applications
- The Two-Colour EMCCD Instrument for the Danish 1.54m Telescope and SONG
- Diffraction-limited CCD imaging with faint reference stars
- AstraLux - the Calar Alto 2.2-m telescope Lucky Imaging camera
- Lucky Exposures: Diffraction limited astronomical imaging through the atmosphere
- Radial-velocity study of the post-period minimum cataclysmic variable SDSSJ143317.78+101123.3 with an electron-multiplying CCD
- An investigation of lucky imaging techniques
- Low light level CCDs and visibility parameter estimation
- Puoko-nui: a flexible high-speed photometric system
- Improvements for group delay fringe tracking
- GravityCam: Wide-Field High-Resolution High-Cadence Imaging Surveys in the Visible from the Ground
- Tantalum STJ for Photon Counting Detectors