Curving X-ray detectors for astrophysics applications
arXiv:2609.01898
Abstract
Next-generation X-ray optics will revolutionize high-energy astrophysics, yet they present several challenges to design a complementary focal plane. In particular, the focal surface is curved, requiring many small, flat sensors to achieve a large field. We present work building on MIT Lincoln Laboratory technology to curve the sensor itself, improving image quality and reducing complexity. Applying this technology to back-illuminated, large-format CCDs having well-characterized X-ray response, we describe the process and report success curving functional BI CCDs to a 2.5-m radius of curvature, achieving RMS curvature deviations less than 1 micron. We confirm that there is no appreciable increase in dark current and that the spectroscopic performance across the 0.3-6 keV band remains excellent. These results demonstrate that curved, large-format X-ray sensors are realizable, and the process can be extended to silicon detectors with other architectures, including active pixel sensors.
13 pages, 9 figures, to appear in Proceedings of the SPIE Astronomical Telescopes + Instrumentation 2026