The FLARE Facility
arXiv:2608.17332
Abstract
The Facility for Laboratory Reconnection Experiments (FLARE) has been constructed to study magnetic reconnection in multiple X-line regimes relevant to space, astrophysical, and fusion plasmas. Building upon the successful design of the Magnetic Reconnection Experiment (MRX), FLARE features a larger physical volume, stronger magnetic fields, and an independent ohmic heating drive to significantly extend the accessible parameter space, targeting Lundquist numbers up to S ~ 10^5 and normalized system sizes up to λ~ 10^3. This paper details the facility's core engineering components, including the primary vacuum vessel, internal flux cores, highly segmented external coil systems, modular capacitor banks, and the safety interlock and control architecture. An initial diagnostic suite is presented, comprising high-resolution 2D magnetic probe arrays, triple Langmuir probes, a fully fiber-coupled interferometer, ion Doppler spectroscopy, and fast camera imaging. Initial operations demonstrate the device's experimental flexibility and reliability, successfully executing symmetric push-pull reconnection, spheromak merging, and asymmetric downstream configurations. Currently operating within "Stage 2.5" with S ~ 2,500 and λ~ 60 for anti-parallel reconnection, FLARE provides immediate access to the multiple X-line regimes. Planned hardware upgrades, advanced diagnostic additions, and integration with fully kinetic simulations will further expand its capabilities as it transitions into a collaborative user facility for the broader plasma science community.
47 pages, 25 figures, 7 tables