medical imaging

FORCE-Interior: Measurement-Consistent Adaptation of a Poisson-Flow Generative Prior for Interior CT

arXiv:2607.14320

summary

The paper introduces FORCE-Interior, a Poisson‑flow generative reconstruction framework that incorporates measurement‑constrained initialization and per‑step data consistency to improve interior CT reconstruction from truncated projection data.

Abstract

Interior tomography reconstructs a region of interest (ROI) from truncated projections, an ill-posed problem with non-unique solutions and truncation-induced bias. Existing deep-learning methods can be sensitive to changes in ROI geometry and noise, while expressive generative priors may produce measurement-inconsistent content without measurement constraints. We propose FORCE-Interior, a training-free adaptation of a pretrained Poisson-flow generative prior to interior CT. A full-field-of-view (FOV) OS-SART warm start avoids forcing all measured attenuation into the ROI, and truncation-mask-aware OS-SART updates enforce data consistency throughout sampling. In our experiment, FORCE-Interior achieves the best PSNR, SSIM, and LPIPS at the two more severely truncated synthetic ROI sizes and competitive performance at the largest ROI, while maintaining low projection-domain residuals. These findings support the measurement-consistent adaptation of a reusable generative CT prior, while further clinical and patient-level validation remains necessary.

Topics & keywords

#interior tomography#generative models#poisson flow#data consistency#computed tomographyPoisson flowgenerative priortruncated projectionsROI reconstructionmeasurement consistency
FORCE-Interior: Measurement-Consistent Adaptation of a Poisson-Flow Generative Prior for Interior CT · wovepaper