Low-Noise SiPM Light Readout and ASIC-Based Charge Readout of a Liquid Argon Time Projection Chamber for MeV Gamma-Ray Measurements

arXiv:2607.11336

Abstract

We have developed a compact liquid argon time projection chamber (LArTPC), NanoGRAMS, as a technology demonstrator for the Gamma-Ray and AntiMatter Survey (GRAMS). LArTPCs have the potential to enable Compton cameras with unprecedented effective area in the MeV gamma-ray band. NanoGRAMS has an active volume of and is equipped with a low-noise scintillation and charge readout system. The scintillation light is detected by an array of 16 SiPMs ( each), whose signals are summed and amplified by a low-noise transimpedance amplifier operable at liquid argon temperature. Ionization electrons are read out with -pitch pixels and processed by VATA-SGD ASICs, with synchronization provided by an FPGA-based data acquisition system. We irradiated the detector with a source (1173 and ) and successfully detected both 1-hit and 2-hit events. The collected charge was converted to deposited energy using a phenomenological recombination model, and the detector response was evaluated with a Geant4-based Monte Carlo simulation. The reconstructed energy spectrum shows Compton edges at 963 and , consistent with the expected values. For 2-hit events, the sequence of interactions was identified, and the reconstructed back-projection image agrees with the source position. These results demonstrate the feasibility of NanoGRAMS as a Compton camera for MeV gamma-ray imaging spectroscopy.

8 pages, 7 figures, accepted for publication in NIM-A