Self-Error Correcting Method for Magnetic-Array-Type Current Sensors in Multi-Core Cable Applications
arXiv:2512.07521
Abstract
Data-driven methods enable online assessment of error states in magnetic-array-type current sensors, and long-term measurement stability can be enhanced through further self-error correction. However, when the magnetic-array-type current sensors are applied to multi-conductor systems such as multi-core cables, the time-varying correlations among conductor currents may degrade the performance of multi-latent-variable data-driven models for error evaluation. To address this issue, this paper proposes a robust self-error correcting method for magnetic-array-type current sensors even under significant variations in phase current correlations (e.g., large fluctuations in three-phase current imbalance). By incorporating phase current decoupling and principal component analysis (PCA), the correlation analysis of multi-latent variables (i.e., multi-conductor currents) is transformed into a single-latent-variable (corresponding to single phase current) modeling problem. Experimental results demonstrate that the proposed method effectively detects error drifts of magnetic field sensors as low as in relative error and rad in phase error. Accurate evaluation and correction of each magnetic field sensor's error drifts substantially eliminates the overall error drift in the magnetic-array-type current sensor, validating the feasibility and effectiveness of the proposed self-error correcting method.
13 pages, 14 figures