Tritiated methane reduction in the PandaX-4T experiment via purge and cryogenic distillation processes
arXiv:2510.24090
Abstract
Tritium from tritiated methane (CHT) calibration is a significant impurity that restricts the sensitivity of the PandaX-4T dark matter detection experiment in the low-energy region. The CHT removal is essential for PandaX-4T and other liquid xenon dark matter direct detection experiments, as CHT serves as a critical component for low-energy calibration. To eliminate CHT, the xenon in the detector is suitably recuperated, leaving 1.8 bar of xenon gas inside, and the detector is flushed with heated xenon gas. Concurrently, leveraging the lower boiling point of methane relative to xenon, the PandaX-4T cryogenic distillation system is effectively utilized to extract CHT from xenon after optimizing the operational parameters. Following the commissioning run, 5.7 tons of xenon are purified via the distillation method. Recent data indicate that the CHT concentration reduces from mol/mol to mol/mol, demonstrating that gas purging and distillation are effective in removing CHT, even at concentrations on the order of mol/mol.
21 pages, 9 figures