Positron Transport System for Muonium-to-Antimuonium Conversion Experiment
arXiv:2508.07922 · doi:10.1103/2yb7-zv76
Abstract
Muonium-to-Antimuonium Conversion Experiment (MACE) aims to find the charged lepton flavor violation (cLFV) process. A key component of MACE is the positron transport system (PTS) to collect and transport atomic positrons from antimuonium decays, which consists of an electrostatic accelerator and a solenoid beamline. Through field simulations in \textsc{COMSOL} and particle transport simulations based on \textsc{Geant4}, the PTS can achieve a geometric acceptance of the signal at 65.81(4)\% along with a position resolution of 88(1)~m~~102(1)~m. The system achieves 322.4(1)~ns transit time with a spread of 6.9(1)~ns, which allows for a TOF-based rejection of internal conversion backgrounds by a factor of . These promising results pave the way for new-physics signal identifications and background rejections in MACE and offer a novel paradigm for internal transport system in high-intensity frontiers.
9 pages, 6 figures. Comments and suggestions are welcome
References in corpus (11)
- Muon Decay and Physics Beyond the Standard Model
- New Bounds from Searching for Muonium to Antimuonium Conversion
- COMET Phase-I Technical Design Report
- Technical design of the phase I Mu3e experiment
- Muonium Decay
- Introduction to Charged Lepton Flavour Violation
- Magnetic Field Dependence of Muonium-antimuonium Conversion
- Lepton flavor violation by two units
- Conceptual Design of the Muonium-to-Antimuonium Conversion Experiment (MACE)
- Lepton flavor violation by three units
- Design of a CsI(Tl) Calorimeter for Muonium-to-Antimuonium Conversion Experiment