First experimental results and optimization study of the portable neutron-gamma imager GN-Vision
arXiv:2501.08792
Abstract
GN-Vision is a compact, dual-modality imaging device designed to simultaneously localize the spatial origin of -ray and slow neutron sources, with potential applications in nuclear safety, security, and hadron therapy. The system utilizes two position-sensitive detection planes, combining Compton imaging techniques for -ray visualization with passive collimation for imaging slow and thermal neutrons (energies below 100 eV). This paper presents the first experimental outcomes from the initial GN-Vision prototype, focused on the development of its neutron imaging capabilities. Following this experimental assessment, we explore the devices performance potential and discuss several Monte Carlo simulation-based optimizations aimed at refining the neutron collimation system. These optimizations seek to improve real-time imaging efficiency and cost-effectiveness, enhancing GN-Visions applicability for future practical deployments.
13 pages, 12 figures, submitted to App. Rad. Isot