Modeling the Differential Rate for Signal Interactions in Coincidence with Noise Fluctuations or Large Rate Backgrounds
arXiv:2411.10671 · doi:10.1103/dn11-wvr4
Abstract
The characteristic energy of a relic dark matter interaction with a detector scales strongly with the putative dark matter mass. Consequently, experimental search sensitivity at the lightest masses will always come from interactions whose size is similar to noise fluctuations and low energy backgrounds in the detector. In this paper, we correctly calculate the net change in measured differential rate due to signal interactions that overlap in time with noise and backgrounds, accounting for both periods of time when the signal is coincident with noise/backgrounds and for the decreased amount of time in which only noise/backgrounds occur. Previous experimental searches have not accounted for this second fundamental effect, and thus either vastly overestimate their experimental search sensitivity (very bad) or use ad hoc conservative cuts which can underestimate experimental sensitivity (not ideal). We find that the detector response to dark matter can be trivially and conservatively understood as long as the true probability of dark matter pileup is small. We also show that introducing random events in the continuous raw data stream (a form of ``salting") provides a correct and practical implementation that correctly accounts for the decreased live time available for noise fluctuations and background events out of coincidence with a true dark matter signal.
26 pages, 8 figures. To be submitted to Physical Review D
References in corpus (15)
- First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
- First results from the CRESST-III low-mass dark matter program
- Low-Mass Dark Matter Search with the DarkSide-50 Experiment
- First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
- Finding an Upper Limit in the Presence of Unknown Background
- Searching for low-mass dark matter particles with a massive Ge bolometer operated above-ground
- Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
- EXCESS workshop: Descriptions of rising low-energy spectra
- Investigation of background electron emission in the LUX detector
- Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile likelihood approach
- Studies of the Earth shielding effect to direct dark matter searches at the China Jinping Underground Laboratory
- A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning
- Dark Matter Induced Power in Quantum Devices
- Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
- Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs