A tensor model for the calibration of air-coupled ultrasonic sensor arrays in 3D imaging
arXiv:2406.14355 · doi:10.1016/j.sigpro.2024.109812
Abstract
Arrays of ultrasonic sensors are capable of 3D imaging in air and an affordable supplement to other sensing modalities, such as radar, lidar, and camera, i.e. in heterogeneous sensing systems. However, manufacturing tolerances of air-coupled ultrasonic sensors may lead to amplitude and phase deviations. Together with artifacts from imperfect knowledge of the array geometry, there are numerous factors that can impair the imaging performance of an array. We propose a reference-based calibration method to overcome possible limitations. First, we introduce a novel tensor signal model to capture the characteristics of piezoelectric ultrasonic transducers (PUTs) and the underlying multidimensional nature of a multiple-input multiple-output (MIMO) sensor array. Second, we formulate and solve an optimization problem based on this model to obtain the calibrated parameters of the array. Third, we assess both our model and the commonly used analytic model using real data from a 3D imaging experiment. The experiment reveals that our array response model we learned with calibration data yields an imaging performance similar to that of the analytic array model, which requires perfect array geometry information.
arXiv comment22 pages, 6 figures. This work has been accepted for publication by Elsevier B.V
References in corpus (7)
- Tensor Decomposition for Signal Processing and Machine Learning
- Tensor Decompositions for Signal Processing Applications From Two-way to Multiway Component Analysis
- A survey of sparse representation: algorithms and applications
- Multisource Self-calibration for Sensor Arrays
- Three more Decades in Array Signal Processing Research: An Optimization and Structure Exploitation Perspective
- Inexact Block Coordinate Descent Algorithms for Nonsmooth Nonconvex Optimization
- Robust Calibration of Radio Interferometers in Non-Gaussian Environment