Experimental demonstration of frequency downconverted arm length stabilization for a future upgraded gravitational wave detector
arXiv:2405.01475 · doi:10.1364/OL.534141
Abstract
Ground-based laser interferometric gravitational wave detectors consist of complex multiple optical cavity systems. An arm-length stabilization (ALS) system has played an important role in bringing such complex detector into operational state and enhance the duty cycle. The sensitivity of these detectors can be improved if the thermal noise of their test mass mirror coatings is reduced. Crystalline AlGaAs coatings are a promising candidate for this. However, traditional ALS system with frequency-doubled 532 nm light is no longer an option with AlGaAs coatings due to the narrow bandgap of GaAs, thus alternative locking schemes must be developed. In this letter, we describe an experimental demonstration of a novel ALS scheme which is compatible with AlGaAs coatings. This ALS scheme will enable the use of AlGaAs coatings and contribute to improved sensitivity of future detectors.
References in corpus (7)
- Advanced LIGO
- Tests of General Relativity with Binary Black Holes from the second LIGO-Virgo Gravitational-Wave Transient Catalog
- Sensitivity and Performance of the Advanced LIGO Detectors in the Third Observing Run
- Substrate-transferred GaAs/AlGaAs crystalline coatings for gravitational-wave detectors: A review of the state of the art
- An arm length stabilization system for KAGRA and future gravitational-wave detectors
- Highly-efficient generation of coherent light at 2128 nm via degenerate optical-parametric oscillation
- High Frame-Rate Phase Camera for High-Resolution Wavefront Sensing in Gravitational-Wave Detectors