Enhancing interferometry using weak value amplification with real weak values
arXiv:2404.00531 · doi:10.1103/PhysRevLett.134.080802
Abstract
We introduce an ultra-sensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA + interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors, {but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise}. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultra-sensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrowband light using real weak values.
3 figures
References in corpus (37)
- Observation of Gravitational Waves from a Binary Black Hole Merger
- Quantum entanglement
- Quantum metrology
- GWTC-3: Compact Binary Coalescences Observed by LIGO and Virgo During the Second Part of the Third Observing Run
- Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
- Colloquium: Understanding Quantum Weak Values: Basics and Applications
- Measuring small longitudinal phase shifts: weak measurements or standard interferometry?
- Graphene Phase Modulator
- Quantum Enhancement of the Zero-Area Sagnac Interferometer Topology for Gravitational Wave Detection
- Enhanced and switchable spin Hall effect of light near the Brewster angle on reflection
- Modes and states in Quantum Optics
- Technical advantages for weak value amplification: When less is more
- Amplifying Single-Photon Nonlinearity Using Weak Measurement
- Amplification of Angular Rotations Using Weak Measurements
- Precision Measurement of the Optical Conductivity of Atomically Thin Crystals via Photonic Spin Hall Effect
- Measuring ultrasmall time delays of light by joint weak measurements
- When amplification with weak values fails to suppress technical noise
- Weak Value Amplification Can Outperform Conventional Measurement in the Presence of Detector Saturation
- Improving the precision of weak measurements by postselection measurement
- Entanglement-assisted weak value amplification
- Approaching quantum-limited metrology with imperfect detectors by using weak-value amplification
- Charge sensing amplification via weak values measurement
- Search for subsolar-mass binaries in the first half of Advanced LIGO and Virgo's third observing run
- Experiment Investigating the Connection between Weak Values and Contextuality
- Heisenberg-scaling measurement of the single-photon Kerr non-linearity using mixed states
- Protecting weak measurements against systematic errors
- Enhanced weak-value amplification via photon recycling
- Post-selected von Neumann measurement with Hermite-Gaussian and Laguerre-Gaussian pointer states
- Phase amplification in optical interferometry with weak measurement
- Heisenberg-limited metrology via weak-value amplification without using entangled resources
- Toward Incompatible Quantum Limits on Multiparameter Estimation
- Improving the precision of weak-value-amplification with two cascaded Michelson interferometers based on Vernier-effect
- Theory of Compression Channels for Postselected Quantum Metrology
- Progress and Perspectives on Weak-value Amplification
- Weak value amplification of photon number operators in the optomechanical interaction
- Isolating noise and amplifying signal with quantum Cheshire cat
- Dual-recycled interference-based weak value metrology
Cited by in corpus (3)
- Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance
- Exploring weak value arguments and Bargmann invariants in -level quantum systems through the Majorana symmetric representation
- Mitigating Source and Detection Noises in Auto-correlative Weak-Value Amplification