Scheme for continuous force detection with a single electron at the level of
arXiv:2402.05998 · doi:10.1103/PhysRevApplied.23.054088
Abstract
The detection of weak forces is a central problem in physics and engineering, ranging in importance from fundamental pursuits such as precision tests of gravity, gravitational-wave detection, and searches for dark matter, to applications such as force microscopy. These pursuits require a low-mass mechanical force transducer with a high quality factor, whose motion can be measured in a quantum-noise-limited manner. Here we study the ultimate example of such a transducer: a single trapped electron. We propose and analyze in detail a new scheme for high-sensitivity continuous force detection using a single trapped electron whose motion is coupled to a microwave cavity field via image currents induced in an antenna. We derive the fundamental and technical limits to the sensitivity of this scheme and show that despite the disparity in size between that of a single electron and the wavelength of the microwave field, it is possible to continuously monitor the charge's zero-point motion and use it as a force detector with a sensitivity as low as in the gigahertz regime. This sensitivity improves on the state-of-the-art by four orders of magnitude and thus paves the way to novel precision experiments.
21 pages, 4 figures
References in corpus (35)
- Cavity Optomechanics
- Introduction to Quantum Noise, Measurement and Amplification
- New Measurement of the Electron Magnetic Moment and the Fine Structure Constant
- Motional Quantum Ground State of a Levitated Nanoparticle from Room Temperature
- Nanomechanical motion measured with precision beyond the standard quantum limit
- A hybrid on-chip opto-nanomechanical transducer for ultra-sensitive force measurements
- Torsion-balance tests of the weak equivalence principle
- Sensitivity and Performance of the Advanced LIGO Detectors in the Third Observing Run
- Ion-trap measurements of electric-field noise near surfaces
- Ultrasensitive force detection with a nanotube mechanical resonator
- Cavity Control of a Single-Electron Quantum Cyclotron:\\Measuring the Electron Magnetic Moment
- Single-Crystal Diamond Nanomechanical Resonators with Quality Factors exceeding one Million
- Gravitational Radiation Detection with Laser Interferometry
- Loss and heating of particles in small and noisy traps
- Ultrasensitive force and displacement detection using trapped ions
- Calculation of Magnetic Field Noise from High-Permeability Magnetic Shields and Conducting Objects with Simple Geometry
- Force and acceleration sensing with optically levitated nanogram masses at microkelvin temperatures
- Mesoscopic physics of nanomechanical systems
- Optically Measuring Force near the Standard Quantum Limit
- Mechanical Quantum Sensing in the Search for Dark Matter
- Penning traps as a versatile tool for precise experiments in fundamental physics
- Acceleration sensing with magnetically levitated oscillators above a superconductor
- Approaching the motional ground state of a 10 kg object
- Resolved-sideband laser cooling in a Penning trap
- Polaronic model of Two Level Systems in amorphous solids
- High sensitivity accelerometry with a feedback-cooled magnetically levitated microsphere
- Heating of a trapped ion induced by dielectric materials
- Electric-Field Noise above a Thin Dielectric Layer on Metal Electrodes
- Fundamental limitation of ultrastrong coupling between light and atoms
- Magnetostatic field noise near metallic surfaces
- Trapped electrons and ions as particle detectors
- Acceleration-induced effects in stimulated light-matter interactions
- Measurement of ultra-low heating rates of a single antiproton in a cryogenic Penning trap
- Spin Dephasing as a Probe of Mode Temperature, Motional State Distributions, and Heating Rates in a 2D Ion Crystal
- Sideband cooling of small ion Coulomb crystals in a Penning trap