Analysis of the spread of SARS-CoV-2 in a hospital isolation room using CFD and Lagrangian Coherent Structures
arXiv:2401.16053 · doi:10.1016/j.physd.2023.133825
Abstract
This research paper presents an analysis of the propagation of the SARS-CoV-2, or other similar pathogens, in a hospital isolation room using computational fluid dynamics (CFD) and Lagrangian Coherent Structures (LCS). The study investigates the airflow dispersion and droplets in the room under air conditioning vent and sanitizer conditions. The CFD simulation results show that both the air conditioner and sanitizer systems significantly influence the dispersion of the virus in the room. The use of LCS enables acquiring a deep understanding of the dispersion of suspended particles, providing insights into the mechanisms of virus transmission. The findings of this study could help in developing strategies for improving the design and operation of isolation rooms to minimize the likelihood of virus dissemination within hospitals.
arXiv comment17 pages
References in corpus (7)
- Lagrangian Descriptors: A Method for Revealing Phase Space Structures of General Time Dependent Dynamical Systems
- Distinguished trajectories in time dependent vector fields
- The hidden geometry of ocean flows
- A Theoretical Framework for Lagrangian Descriptors
- Lagrangian study of the final warming in the southern stratosphere during 2002: Part I. The Vortex Splitting at Upper Levels
- Lagrangian study of the final warming in the southern stratosphere during 2002: Part II. 3D structure
- Mixing and Geometry in the North Atlantic Meridional Overturning Circulation