A new method to measure the unloaded quality factor of superconducting cavities
arXiv:2312.17548 · doi:10.1103/PhysRevAccelBeams.27.032001
Abstract
We describe an method that measures the unloaded quality factor , the external quality factor , and the cavity detuning with a recursive least-squares algorithm. It combines a large number of consecutive measurements to successively improve an estimate of fit parameters that asymptotically converges to the ``real'' values. Exploiting the large amount of data acquired by a digital low-level RF system permits us to reach this asymptotic regime in a moderate time frame of seconds to minutes. Simulations show that the method works both for critically coupled and over-coupled cavities. A new calibration method adresses very tight tolerances of the method on system parameters.
12 pages, 3 figures