A new method to measure the unloaded quality factor of superconducting cavities
arXiv:2312.17548 · doi:10.1103/PhysRevAccelBeams.27.032001
Abstract
We describe an method that measures the unloaded quality factor , the external quality factor , and the cavity detuning with a recursive least-squares algorithm. It combines a large number of consecutive measurements to successively improve an estimate of fit parameters that asymptotically converges to the ``real'' values. Exploiting the large amount of data acquired by a digital low-level RF system permits us to reach this asymptotic regime in a moderate time frame of seconds to minutes. Simulations show that the method works both for critically coupled and over-coupled cavities. A new calibration method adresses very tight tolerances of the method on system parameters.
arXiv comment12 pages, 3 figures
References in corpus (4)
- Systematic Uncertainties in RF-Based Measurement of Superconducting Cavity Quality Factors
- Improved RF Measurements of SRF Cavity Quality Factors
- Intrinsic Quality Factor Extraction of Multi-Port Cavity with Arbitrary Coupling
- Simulations of real-time system identification for superconducting cavities with a recursive least-squares algorithm