Synchrotron-based X-ray Fluorescence Ghost Imaging
arXiv:2306.16258 · doi:10.1364/OL.499046
Abstract
X-ray Fluorescence Ghost Imaging (XRF-GI) was recently demonstrated for x-ray lab sources. It has the potential to reduce acquisition time and deposited dose by choosing their trade-off with spatial resolution, while alleviating the focusing constraints of the probing beam. Here, we demonstrate the realization of synchrotron-based XRF-GI: We present both an adapted experimental setup and its corresponding required computational technique to process the data. This extends the above-mentioned potential advantages of GI to synchrotron XRF imaging. In addition, it enables new strategies to improve resilience against drifts at all scales, and the study of previously inaccessible samples, such as liquids.
arXiv comment4 pages, 5 figures
References in corpus (5)
- Correlated imaging, quantum and classical
- Experimental x-ray ghost imaging
- Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle-Pock algorithm
- Neutron Ghost Imaging
- What are the advantages of ghost imaging? Multiplexing for x-ray and electron imaging