Demonstrating repetitive non-destructive readout (RNDR) with SiSeRO devices
arXiv:2305.01900 · doi:10.1117/1.JATIS.10.1.016004
Abstract
We demonstrate so-called repetitive non-destructive readout (RNDR) for the first time on a Single electron Sensitive Readout (SiSeRO) device. SiSeRO is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors, developed at MIT Lincoln Laboratory. This technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. RNDR was realized by transferring the signal charge non-destructively between the internal gate and the summing well (SW), which is the last serial register. The advantage of the non-destructive charge transfer is that the signal charge for each pixel can be measured at the end of each transfer cycle and by averaging for a large number of measurements (), the total noise can be reduced by a factor of 1/. In our experiments with a prototype SiSeRO device, we implemented nine ( = 9) RNDR cycles, achieving around 2 electron readout noise (equivalent noise charge or ENC) with spectral resolution close to the fano limit for silicon at 5.9 keV. These first results are extremely encouraging, demonstrating successful implementation of the RNDR technique in SiSeROs. They also lay foundation for future experiments with more optimized test stands (better temperature control, larger number of RNDR cycles, RNDR-optimized SiSeRO devices) which should be capable of achieving sub-electron noise sensitivities. This new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring very low-noise spectroscopic imagers. The sub-electron sensitivity also adds the capability to conduct in-situ absolute calibration, enabling unprecedented characterization of the low energy instrument response.
Accepted for publication in Journal of Astronomical Telescopes, Instruments, and Systems (JATIS). arXiv admin note: text overlap with arXiv:2208.01082
References in corpus (7)
- Single-electron and single-photon sensitivity with a silicon Skipper CCD
- Overview of the Advanced X-ray Imaging Satellite (AXIS)
- Simulations and Design of a Single-Photon CMOS Imaging Pixel Using Multiple Non-Destructive Signal Sampling
- First results on SiSeRO (Single electron Sensitive Read Out) devices -- a new X-ray detector for scientific instrumentation
- Improved noise performance from the next-generation buried-channel p-Mosfet SiSeROs
- Fiber positioning in microlens-fiber coupled integral field unit
- Tiny-box: A tool for the versatile development and characterization of low noise fast X-ray imaging detectors