Line positions and intensities of the band of CHI using mid-infrared optical frequency comb Fourier transform spectroscopy
arXiv:2303.10066 · doi:10.1016/j.jqsrt.2023.108646
Abstract
We present a new spectral analysis of the and +- bands of CHI around 2971 cm based on a high-resolution spectrum spanning from 2800 cm to 3160 cm, measured using an optical frequency comb Fourier transform spectrometer. From this spectrum, we previously assigned the and +- bands around 3060 cm using PGOPHER, and the line list was incorporated in the HITRAN database. Here, we treat the two fundamental bands, and , together with the perturbing states, 2+ and +2, as a four-level system connected via Coriolis and Fermi interactions. A similar four-level system is assumed to connect the +- and +- hot bands, which appear due to the population of the low-lying state at room temperature, with the 2+2 and +- perturbing states. This treatment provides a good global agreement of the simulated spectra with experiment, and hence accurate line lists and band parameters of the four connected vibrational states in each system. Overall, we assign 4665 transitions in the fundamental band system, with an average error of 0.00071 cm, a factor of two better than earlier work on the band using conventional Fourier transform infrared spectroscopy. The band shows hyperfine splitting, resolvable for transitions with J 2 x K. Finally, the spectral intensities of 65 lines of the band and 7 lines of the +- band are reported for the first time using the Voigt line shape as a model in multispectral fitting.
References in corpus (7)
- Quantum-noise-limited optical frequency comb spectroscopy
- Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs
- Optical Frequency Comb Fourier Transform Spectroscopy with Sub-Nominal Resolution - Principles and Implementation
- High-power frequency comb source tunable from 2.7 to 4.2 μm based on difference frequency generation pumped by an Yb-doped fiber laser
- Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution
- Sub-Doppler Double-Resonance Spectroscopy of Methane Using a Frequency Comb Probe
- Alternative Methylated Biosignatures I: Methyl Bromide, A Capstone Biosignature
Cited by in corpus (4)
- Data availability and requirements relevant for the Ariel space mission and other exoplanet atmosphere applications
- Precision frequency comb spectroscopy of the NO, NNO, NNO, and NO isotopocules in the 3300-3550 cm range
- Precision spectroscopy of non-thermal molecular plasmas using mid-infrared optical frequency comb Fourier transform spectroscopy
- Formation of HNC and HCN isomers in molecular plasmas revealed by frequency comb and quantum cascade laser spectroscopy