New results from the technological prototype of the CALICE highly-granular silicon tungsten electromagnetic calorimeter
arXiv:2211.05614 · doi:10.1016/j.nima.2023.168185
Abstract
An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common set. The noise, self-trigger performances and response to punch-though electrons, without tungsten absorbers, have been evaluated for each of the 15360 channels, using an improved procedure. Showers of low-energy electrons (1 to 6 GeV) have been recorded in two configurations of absorber, and are being analysed. Some preliminary results at the cell level will be presented.
arXiv commentProceedings of the PISA'22 conference, for the CALICE collaboration
References in corpus (7)
- Particle Flow Calorimetry and the PandoraPFA Algorithm
- The DESY II Test Beam Facility
- Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
- EUDAQ A Data Acquisition Software Framework for Common Beam Telescopes
- Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC
- CALICE SiW ECAL -- Development and performance of a highly compact digital readout system
- Coherent noise source identification in multi channel analysis