Benchmarking between fluid and global models for low-pressure oxygen DC glow discharges
arXiv:2210.16608 · doi:10.1088/1361-6595/acbb9c
Abstract
This work focuses on the benchmarking between a zero-dimensional (0D) global model (LoKI) and a one-dimensional (1D) radial fluid model for the positive column of oxygen DC glow discharges in a tube of 1 cm inner radius at pressures between 0.5 Torr and 10 Torr. The data used in the two models are the same, so that the difference between the models is reduced to dimensionality. A good agreement is found between the two models on the main discharge parameters, with relative differences below 5%. The agreement on species average number densities, charged and neutral, is slightly worse, with relative differences increasing with pressure from 11% at 0.5 Torr to 57% at 10 Torr. The success of the 0D global model in describing these plasmas through volume averaged quantities decreases with pressure, due to pressure-driven narrowing of radial profiles. Hence, in the studied conditions, we recommend the use of volume-averaged models only in the pressure range up to 10 Torr.
arXiv comment31 pages, 11 figures
References in corpus (5)
- Kinetic Theory of Plasmas: Translational Energy
- Dynamic Contraction of the Positive Column of a Self-Sustained Glow Discharge in Air Flow
- Zero-dimensional and pseudo-one-dimensional models of atmospheric-pressure plasma jet in binary and ternary mixtures of oxygen and nitrogen with helium background
- An asymptotic preserving well-balanced scheme for the isothermal fluid equations in low-temperature plasma applications
- Kinetic theory of two-temperature polyatomic plasmas