Bubble collapse near porous plates
arXiv:2210.03614 · doi:10.1017/jfm.2023.266
Abstract
The collapse of a gas or vapour bubble near a non-porous boundary is directed at the boundary due to the asymmetry induced by the nearby boundary. High surface pressure and shear stress from this collapse can damage, or clean, the surface. A porous boundary, such as a filter, would act similarly to a non-porous boundary but with reduced asymmetry and thus reduced effect. Prior research has measured the cleaning effect of bubbles on filters using ultrasonic cleaning, but it is not known how the bubble dynamics are fundamentally affected by the porosity of the surface. We address this question experimentally by investigating how the standoff distance, porosity, pore size, and pore shape affect two collapse properties: bubble displacement and bubble rebound size. We show that these properties depend primarily on the standoff distance and porosity of the boundary and extend a previously developed numerical model that approximates this behaviour. Using the numerical model in combination with experimental data, we show that bubble displacement and bubble rebound size each collapse onto respective single curves.
References in corpus (6)
- Scaling laws for jets of single cavitation bubbles
- Shock waves from non-spherical cavitation bubbles
- The Quest for the Most Spherical Bubble
- The direction of the microjet produced by the collapse of a cavitation bubble locatedin between a wall and a free surface
- Cavity collapse near slot geometries
- Jet direction in bubble collapse within rectangular and triangular channels