Timing performance of radiation hard MALTA monolithic Pixel sensors
arXiv:2209.14676 · doi:10.1088/1748-0221/18/03/C03011
Abstract
The MALTA family of Depleted Monolithic Active Pixel Sensor (DMAPS) produced in Tower 180 nm CMOS technology targets radiation hard applications for the HL-LHC and beyond. Several process modifications and front-end improvements have resulted in radiation hardness up to and time resolution below 2 ns, with uniform charge collection efficiency across the Pixel of size with a electrode size. The MALTA2 demonstrator produced in 2021 on high-resistivity epitaxial silicon and on Czochralski substrates implements a new cascoded front-end that reduces the RTS noise and has a higher gain. This contribution shows results from MALTA2 on timing resolution at the nanosecond level from the CERN SPS test-beam campaign of 2021.
8 pages, 8 figures. Submitted to Journal of Instrumentation (JINST). Proceedings of the 23rd International Workshop on Radiation Imaging Detectors IWORID 2022