Design of the High Rigidity Spectrometer at FRIB
arXiv:2207.05995 · doi:10.1016/j.nima.2022.167548
Abstract
A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (100MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. The maximum magnetic rigidity of the HRS is 8Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.
arXiv comment24 pages, 26 figures, 6 tables
References in corpus (9)
- Nuclear landscape in covariant density functional theory
- SRIT: A time-projection chamber for symmetry-energy studies
- Time-of-flight mass measurements for nuclear processes in neutron star crusts
- Mass Measurements Demonstrate a Strong N =28 Shell Gap in Argon
- Extraction of 3D field maps of magnetic multipoles from 2D surface measurements with applications to the optics calculations of the large-acceptance superconducting fragment separator BigRIPS
- Constraining the Neutron Star Compactness: Extraction of the Al() Reaction Rate for the -Process
- Digital Data Acquisition For the Low Energy Neutron Detector Array (LENDA)
- Development of a novel MPGD-based drift chamber for the NSCL/FRIB S800 spectrometer
- Plastic Scintillation Detectors for Time-of-Flight Mass Measurements